- Home
- Products
- Water softening
- TYS Series Water Softening System

Water softening
TYS Series Water Softening System
TYS Series duplex water softening systems are equipped with fully automatic control systems and consist of two softening units. The system can be controlled volumetrically according to the quantity of water passing through.
- Twin-tank, corrosion-resistant FRP (filament-wound) vessel
- Programmable automatic valve
- Flow-controlled automatic regeneration
- 3–6 bar operating pressure
Overview
Advantages
- Prevents scale formation.
- Increases the energy efficiency of heating systems.
- Extends the service life of boilers, heat exchangers and piping.
- Reduces soap and detergent consumption.
- Reduces maintenance and repair costs.
- Improves product quality in industrial processes.
- Maintains the performance of water-using equipment.
SYSTEM FEATURES
- Twin-tank, corrosion-resistant FRP (filament-wound) vessel
- Programmable automatic valve
- Flow-controlled automatic regeneration
- 3–6 bar operating pressure
- Maximum 10 bar test pressure
- Maximum operating temperature of 50 °C
- Ion exchange resin compliant with food regulations
- 220 V / 50 Hz power supply
Areas of Use
- Houses and villas
- Hotels and Hospitality Facilities
- Hospitals
- Industrial production facilities
- Boiler feed water systems
- Cooling towers
- Laundries
- Food and beverage production facilities
- Car wash facilities
- Agricultural enterprises
Technical data
Standard models. Every project is sized from your water analysis.
TYS MODELS TECHNICAL SPECIFICATIONS17 rows
| Model | SERVICE FLOW RATE (m³/h) | PRESSURE DROP (bar) | SERVICE (inch) | DRAIN (inch) | DIMENSIONS (cm) | RESIN (L) | BRINE TANK (L) | |||
|---|---|---|---|---|---|---|---|---|---|---|
| 20 m³/h | 30 m³/h | LA | LB | D | ||||||
| TYS 30 | 1.5x2 | 2x2 | 0.2 | 3/4 | 1/2 | 104 | 89 | 25 | 30x2 | 70x2 |
| TYS 50 | 1.5x2 | 2x2 | 0.2 | 3/4 | 1/2 | 153 | 137 | 25 | 50x2 | 70x2 |
| TYS 60 | 2.2x2 | 3x2 | 0.2 | 3/4 | 1/2 | 148 | 132 | 30 | 60x2 | 70x2 |
| TYS 80 | 2.5x2 | 3.5x2 | 0.2 | 1 | 1/2 | 153 | 137 | 33 | 80x2 | 100x2 |
| TYS 100 | 3x2 | 4x2 | 0.2 | 1 | 1/2 | 181 | 165 | 36 | 100x2 | 100x2 |
| TYS 150 | 4x2 | -- | 0.2 | 1 | 1/2 | 181 | 165 | 41 | 150x2 | 140x2 |
| TYS 150 | 4x2 | 5.5x2 | 0.2 | 1 | 1/2 | 181 | 165 | 41 | 150x2 | 140x2 |
| TYS 200 | 5.1x2 | 6.5x2 | 0.3 | 1 | 1/2 | 181 | 165 | 46 | 200x2 | 200x2 |
| TYS 150 | 4x2 | 5.5x2 | 0.2 | 2 | 1 | 187 | 165 | 41 | 150x2 | 140x2 |
| TYS 200 | 5.1x2 | 6.5x2 | 0.3 | 2 | 1 | 187 | 165 | 46 | 200x2 | 200x2 |
| TYS 250 | 6.6x2 | 9x2 | 0.5 | 2 | 1 | 182 | 152 | 53 | 250x2 | 300x2 |
| TYS 300 | 9x2 | 10x2 | 0.5 | 2 | 1 | 235 | 183 | 61 | 300x2 | 300x2 |
| TYS 500 | 10x2 | ---- | 0.7 | 2 | 1 | 235 | 183 | 76 | 500x2 | 500x2 |
| TYS 750 | 12x2 | ---- | 0.7 | 2 | 1 | 235 | 183 | 92 | 750x2 | 750x2 |
| TYS 500 | 14x2 | 15x2 | 0.7 | 2 | 2 | 235 | 183 | 92 | 500x2 | 500x2 |
| TYS 750 | 18x2 | -- | 0.7 | 2 | 2 | 235 | 183 | 92 | 750x2 | 750x2 |
| TYS 900 | 20x2 | -- | 0.7 | 2 | 2 | 247 | 183 | 105 | 900x2 | 1000x2 |
Reference projects
Reference projects using this system
5-star hotel filtration and softening
5,000m³/daySand filter, activated carbon, softening
Laundry plant softening
3,000m³/daySoftening system
Water softening
More in water softening

ZKYS Series Water Softening System
With ZKYS Series time-controlled water softening systems, calcium and magnesium ions in the water are removed by the ion exchange principle.
- Corrosion-resistant FRP (filament-wound) vessel
- Programmable automatic valve

DKYS Series Water Softening System
DKYS Series flow-controlled water softening systems measure the quantity of water passing through by means of a meter on the unit and subject it to a…
- Corrosion-resistant FRP (filament-wound) vessel
- Programmable automatic valve

ETYS Series Water Softening System
With ETYS Frontal-Piped Single, Duplex and Triplex water softening systems, calcium and magnesium ions in the water are removed by the ion exchange…
- Cationic resin, maximum operating pressure 6 bar
- Octopus diffuser bottom collector structure
Request a quote
Ready to talk about your water?
Capacity and source water are enough to start. A full analysis lets our engineers choose the right membranes and pre-treatment.