An iron and manganese removal system is a special water treatment system that removes dissolved iron (Fe) and manganese (Mn) ions naturally present in groundwater and surface water, improving the colour, taste and quality of the water.
- Connection Options: Threaded or flanged connection.
Overview
WHAT IS AN IRON AND MANGANESE REMOVAL SYSTEM?
- An iron and manganese removal system is a special water treatment system that removes dissolved iron and manganese ions from water by oxidation and filtration methods.
- Iron and manganese are generally present in dissolved form in groundwater. When these minerals come into contact with air, they oxidise and begin to precipitate. Iron forms brown deposits and manganese forms black deposits, which spoil the appearance of the water and cause build-up in piping systems.
- In the systems developed by AFG, these minerals are removed effectively by using a suitable oxidation method and high-performance filter media.
PROBLEMS CAUSED BY IRON AND MANGANESE
- Water with a high iron and manganese concentration may cause the following problems:
- Brown or black stains on taps and sinks
- Colour change in laundry
- Deposits and blockages in piping systems
- Loss of performance in pumps and valves
- Reduced efficiency in heat exchangers
- Build-up in boiler systems
- Quality problems in food and beverage production
Show all 11
- Fouling in membrane systems
- Deterioration in the taste and odour of the water
- Increase in maintenance and operating costs
HOW DOES AN IRON AND MANGANESE REMOVAL SYSTEM WORK?
- AFG systems may consist of different processes according to the water analysis.
- 1. Pre-Filtration: Sand, sediment and suspended solids in the raw water are retained in mechanical filters.
- 2. Oxidation: Dissolved iron and manganese are converted into an insoluble form with the help of oxidants such as oxygen, air, chlorine, potassium permanganate or ozone.
- 3. Filtration: The oxidised iron and manganese are separated from the water by passing through special filter media. The filter media used may include options such as Manganese Dioxide-Based Media, Greensand Plus, Catalytic Media, Birm, Filox, Pyrolox, MangOx and catalytic sand.
- 4. Automatic Backwash: Contaminants accumulated in the filter bed are removed from the system by automatic backwashing at set intervals.
ADVANTAGES OF AFG IRON AND MANGANESE REMOVAL SYSTEMS
- High iron and manganese removal efficiency
- Low operating cost
- Fully automatic operation and PLC-controlled automation
- Automatic backwash system
- Low maintenance requirement and long-life filter media
- Modular design and energy-efficient operation
- Capacity options suitable for different flow rates
- Easy installation and service
Technical Specifications
- Filter Body: FRP (Fibre Reinforced Polyester), epoxy-painted carbon steel, AISI 304 or AISI 316L stainless steel.
- Control System: Time-controlled or flow-controlled automatic valve, PLC-controlled automation, touchscreen HMI (optional).
- Connection Options: Threaded or flanged connection.
- Operating Conditions: Operating pressure 2–8 bar (may vary depending on the project), operating temperature 5°C – 45°C.
- Filter Media: Special iron and manganese removal media selected according to the water analysis.
Areas of Use
- AFG Iron and Manganese Removal Systems are used reliably in the following areas:
- Municipalities: Reduction of iron and manganese levels in drinking water networks.
- Village and Neighbourhood Drinking Water Facilities: Bringing well water into compliance with drinking water standards.
- Hotels and Tourism Facilities: Improving guest utility water quality and protecting installations.
- Industrial Facilities: Improving process water quality and extending equipment life.
- Food and Beverage Industry: Preventing unwanted colour, taste and sediment in production processes.
- Textile Industry: Improving water quality in dyeing processes.
- Power Plants: In boiler feed water pre-treatment systems.
- Agricultural Irrigation: Preventing clogging in drip irrigation systems.
- Residential and Housing Estate Projects: In central water treatment systems.
WHY AFG?
- AFG designs each project specifically according to the water analysis. Instead of a one-size-fits-all solution, the most suitable process is determined by taking into account the iron and manganese concentration of the water, pH value, dissolved oxygen level, flow rate requirement and intended use.
- Our services: Water analysis evaluation, project planning and engineering, system design, manufacturing and installation, commissioning, operator training, periodic maintenance, spare parts supply and technical service support.
Models
- CORRECT PROCESS SELECTION IN IRON AND MANGANESE REMOVAL SYSTEMS
- The chemical composition of every water source is different. Therefore, a single filter medium or a standard system may not be suitable for every application. AFG develops high-efficiency solutions by determining the oxidation method, filter media and automation structure according to a detailed water analysis. When required, the systems are integrated with activated carbon filters, water softening units, reverse osmosis (RO) systems and ultraviolet (UV) disinfection units to create comprehensive water treatment solutions.
Reference projects
Reference projects using this system
Manisa municipal drinking water plant
9,225m³/dayArsenic, iron and manganese removal unit
Contaminant removal
More in contaminant removal

Arsenic Removal System
An arsenic removal system is an advanced water treatment technology used to reduce arsenic, which may occur in groundwater and surface water sources…
- Automatic or manual control options
- FRP, carbon steel or stainless steel filter vessel

Boron Removal Systems
A boron removal system is a water treatment system used to reduce the boron concentration found in natural waters, groundwater, surface waters or…
View product →Request a quote
Ready to talk about your water?
Capacity and source water are enough to start. A full analysis lets our engineers choose the right membranes and pre-treatment.