- Home
- Products
- Filtration
- AKFS Series Activated Carbon Filtration System

Filtration
AKFS Series Activated Carbon Filtration System
AKFS Activated Carbon Filtration Systems use the adsorption property of activated carbon to draw the molecules and ions in the water towards the inner surfaces through the mineral pores, leaving the water free of organic matter, colourless, odourless and clear.
- Corrosion-resistant FRP (filament-wound) vessel
- Programmable automatic valve
- Automatic backwash time adjuster
- Operating pressure: 3-6 bar
Overview
SYSTEM FEATURES
- Corrosion-resistant FRP (filament-wound) vessel
- Programmable automatic valve
- Automatic backwash time adjuster
- Operating pressure: 3-6 bar
- Max. test pressure: 10 bar
- Max. temperature: 50 °C
- Media content in 3 different granule sizes
- Power supply: 220V / 50 Hz
Areas of Use
- Drinking water treatment plants
- Reverse osmosis (RO) pre-treatment
- Ultrafiltration (UF) pre-treatment
- Food and beverage production facilities
- Pharmaceutical and cosmetics industry
- Hotels and Hospitality Facilities
- Hospitals
- Industrial process water
- Bottling plants
- Municipal water treatment systems
Advantages
- Removes chlorine with high efficiency.
- Gives the water a natural taste and odour.
- Reduces the organic contaminant load.
- Protects reverse osmosis (RO) membranes against the effects of chlorine.
- Helps to reduce chemical consumption.
- Has low operating and maintenance costs.
- Offers long-lasting filter media.
Technical data
Standard models. Every project is sized from your water analysis.
AKFS MODELS TECHNICAL DATA TABLE16 rows
| Model | SERVICE FLOW RATE (m³/h) | PRESSURE DROP (bar) | SERVICE (inch) | DRAIN (inch) | DIMENSIONS (cm) | CARBON (kg) | QUARTZ (kg) | |||
|---|---|---|---|---|---|---|---|---|---|---|
| 20 m/h | 30 m/h | LA | LB | D | ||||||
| AKFS 20 | 1 | 1.5 | 0.2 | 3/4 | 3/4 | 104 | 89 | 25 | 20 | --- |
| AKFS 25 | 1 | 1.5 | 0.2 | 3/4 | 3/4 | 153 | 137 | 25 | 25 | --- |
| AKFS 35 | 1.5 | 2.2 | 0.2 | 1 | 1 | 148 | 132 | 30 | 35 | --- |
| AKFS 40 | 1.75 | 2.5 | 0.3 | 1 | 1 | 153 | 137 | 33 | 40 | 15 |
| AKFS 50 | 2 | 3 | 0.3 | 1 | 1 | 181 | 165 | 36 | 50 | 25 |
| AKFS 75 | 2.5 | 4 | 0.3 | 1 | 1 | 181 | 165 | 41 | 75 | 50 |
| AKFS 80 | 3.5 | ---- | 0.5 | 1 | 1 | 181 | 165 | 46 | 80 | 50 |
| AKFS 75 | 2.5 | 4 | 0.3 | 2 | 2 | 187 | 165 | 41 | 75 | 25 |
| AKFS 80 | 3.5 | 5 | 0.5 | 2 | 2 | 187 | 165 | 46 | 80 | 50 |
| AKFS 100 | 4.5 | 6 | 0.5 | 2 | 2 | 182 | 152 | 53 | 100 | 50 |
| AKFS 125 | 6 | 9 | 0.5 | 2 | 2 | 235 | 183 | 61 | 125 | 100 |
| AKSF 200 | 9 | ---- | 1 | 2 | 2 | 235 | 183 | 76 | 200 | 150 |
| AKFS 300 | 10 | ---- | 1 | 2 | 2 | 235 | 183 | 92 | 300 | 150 |
| AKFS 300 | 14 | 18 | 1 | 2 | 2 | 235 | 183 | 92 | 300 | 150 |
| AKFS 450 | 18 | 20 | 1 | 2 | 2 | 247 | 183 | 105 | 450 | 200 |
| AKFS 750 | 18 | 20 | 1 | 2 | 2 | 247 | 183 | 105 | 750 | 200 |
Reference projects
Reference projects using this system
5-star hotel filtration and softening
5,000m³/daySand filter, activated carbon, softening
5-star hotel seawater plant
1,200m³/daySelf-cleaning filter, UF, SWRO, dolomite, sand filter, RO
5-star hotel seawater plant
1,000m³/daySelf-cleaning filter, SWRO, dolomite, sand filter
5-star hotel seawater plant
360m³/daySelf-cleaning filter, SWRO, dolomite, sand filter
Filtration
More in filtration

KFS Series Sand Filtration System
The KFS Series Sand Filtration System consists of 3 main components: Control Unit, Filter Body and Filter Media. With the help of the media inside…
- Corrosion-resistant FRP (filament-wound) vessel
- Programmable automatic valve

EKFS Series Sand Filtration System
It consists of 3 main components: the Control Unit, comprising valves with electric or pneumatic actuators under PLC control, the Filter Vessel and…
- Maximum operating pressure 6 bar
- Time-controlled backwash (differential pressure optional)

EAKFS Series Activated Carbon Filtration System
AKFS Activated Carbon Filtration Systems use the adsorption property of activated carbon to draw the molecules and ions in the water towards the…
- Corrosion-resistant FRP (filament-wound) vessel
- Programmable automatic valve
Request a quote
Ready to talk about your water?
Capacity and source water are enough to start. A full analysis lets our engineers choose the right membranes and pre-treatment.